Thermal Evaluation of Solar Water Desalination System with Evacuated Tubes
Journal: International Journal of Applied and Natural Sciences (IJANS) (Vol.6, No. 1)Publication Date: 2017-01-31
Authors : S. R. Kalbande; Priyanka Nayak; Sneha Deshmukh; V. P. Khambalkar;
Page : 41-54
Keywords : Evacuated Tubes; Heat Transfer Coefficients; Heat Transfer Rate; Solar Still;
Abstract
A solar still coupled with evacuated tube collector was designed and developed for distillation of water. As the wind velocity increased, the convective heat loss from glass cover to ambient increased, hence the glass cover temperature decreased which helped to increase the water glass cover temperature difference thereby the overall yield increased. Heat loss coefficient increases until it reaches maximum in solar noon due to high temperature difference between the inside still and the ambient temperature at this time, then it decreased at afternoon. The average internal heat transfer coefficient i.e. convective, radiative and evaporative was found to be 3.7, 8.33, 99.24 W/m2K, respectively. The external heat transfer coefficient such as average overall top heat loss coefficient was found to be 9.92 W/m2K as compared to bottom heat loss coefficient 0.31 W/m2K. Therefore distillate yield was found to be maximum.
Other Latest Articles
- Generation of Hydrogen by Corrosion of New nanocomposite Based on Aluminum in Diluted Alkaline Solution
- Mgnrega Implementation Issues and Problems Faced by Beneficaries of Doaba Region of Punjab
- Genetic Diversity Analysis of the Flea Beetle, Podagrica Fuscicornis (Chrysomelidae) using Mitochondrial Cytochrome Oxidase Subunit I Gene Marker
- Obtaining Super-Efficient Estimators for a Real-Valued Parameter: Delta Method
- Numerical Solution of Fourth Order Boundary Value Problems by Petrov-Galerkin Method with Cubic B-splines as Basis Functions and Quartic B-splines as Weight Functions