EFFICIENCY OF USING PUMPS WITH ADJUSTABLE DRIVE FOR PART-LOADED OIL PIPELINE
Journal: International Scientific Journal "Internauka" (Vol.1, No. 24)Publication Date: 2017-02-28
Authors : Serediuk M.; Grygorskyi S.;
Page : 165-172
Keywords : oil pumping station (OPS); pumping unit; regulated drive; flow capacity; specific power consumption; energy efficiency;
Abstract
The possible range of adjustment and energy efficiency for the application of regulated drives for pumps were studied based on the example of operational main oil pipeline segment, which has significant part load. Cases using pumps with regulated drives on one and on all as well oil pumping stations of oil pipeline were investigated.