EFFICIENCY OF USING PUMPS WITH ADJUSTABLE DRIVE FOR PART-LOADED OIL PIPELINE
Journal: International Scientific Journal "Internauka" (Vol.1, No. 24)Publication Date: 2017-02-28
Authors : Serediuk M.; Grygorskyi S.;
Page : 165-172
Keywords : oil pumping station (OPS); pumping unit; regulated drive; flow capacity; specific power consumption; energy efficiency;
- EFFICIENCY OF USING PUMPS WITH ADJUSTABLE DRIVE FOR PART-LOADED OIL PIPELINE
- ADJUSTABLE ELECTRIC DRIVE OF UNBALANCED VIBRO-EXCITER
- TECHNO-ECONOMIC EVALUATION OF PIPELINE COMPRESSION SYSTEM: EVALUATION OF GAS COMPRESSOR POWER IN A NATURAL GAS PIPELINE NETWORK—PART 1
- TECHNO-ECONOMIC EVALUATION OF PIPELINE COMPRESSION SYSTEM: GAS COMPRESSOR OPERATION EVALUATION ON NATURAL GAS PIPELINE NETWORK-PART 2
- THE ANALYSIS OF DYNAMIC PROCESSES IN THE ADJUSTABLE ASYNCHRONOUS ELECTRIC DRIVE OF ARMORED FACE CONVEYOR CP72
Abstract
The possible range of adjustment and energy efficiency for the application of regulated drives for pumps were studied based on the example of operational main oil pipeline segment, which has significant part load. Cases using pumps with regulated drives on one and on all as well oil pumping stations of oil pipeline were investigated.
Other Latest Articles
- DATABASE CREATION FOR VILLAGE LIBRARY USING ALLFUSION PROCESS+DATA MODELER
- THE USE OF REGULAR THERMAL REGIME FOR THERMOPHYSICAL ANALYSIS OF THE MATERIALS TO BE DRIED
- THE ANALYSIS OF THE STATE AND THE PROSPECTS OF DEVELOPMENT OF RENEWABLES IN UZBEKISTAN
- STUDYING THE SORPTION PROCESSES IN SUGAR REDUCED EGG-WHITE CREAMS DURING STORAGE
- INNOVATIVE TECHNOLOGY DETERMINATION OF WATER IN THE COMPOSITION OF VEGETABLE OIL
Last modified: 2017-04-06 22:09:01