POWER OSCILLATION CONTROL IN POWER SYSTEM BY ANFIS BASED UNIFIED POWER FLOW CONTROLLER ALONG WITH STABILIZATION
Journal: International Journal of Engineering Sciences & Research Technology (IJESRT) (Vol.6, No. 5)Publication Date: 2017-05-30
Authors : Chitrasen Gabel; Dharmendra Kumar Singh;
Page : 579-585
Keywords : Power System Stabilizer; Adaptive Neuro Fuzzy Interface; Unified Power Flow Controller; Automatic Voltage Regulator; Multi machine infinite bus; Excitation System.;
Abstract
In the present era, the power system has become a vital part to provide stability enhancement. The stability of a power system depends on how low frequency disturbances which are typically in the frequency range of 0.2 to 3.0 Hz, accurately find out and cleared so that quick restoration and maintains a stability enhancement of power is accomplished. Loss of synchronism and stability enhancement are needs to be performed using ANFIS controlled based excitation of power system [3]. The significant factors which affect the operation of power system during the occurrence of low frequency disturbances are mainly; Loss of synchronism which might be excited by the disturbances in the system or, in some cases, might even build up spontaneously. These factors can be analyzed to find out the occurrence of the low frequency disturbance in the power line operation. Various techniques like Power System Stabilizer with algorithm based or logic controlled based, UPFC has been used in past to find out and cleared the different low frequency disturbances occurred in the transmission line. The proper selection of enhanced feedback is a very tedious and time consuming task and also requires brief knowledge of the system configuration. To avoid the drawbacks of conventional power system stabilizer with algorithm or logic controller based techniques, this dissertation proposed, an efficient and robust technique of stability enhancement using ANFIS based power system excitation. The advantage of the proposed technique is that; it improves the overshoot of power and reduced the time for low frequency oscillations [1]. The ANFIS based stability enhancement accuracy of proposed technique has been verified using MATLAB/Simulink 2013(a) software. The obtained results show that the proposed technique is efficient in stability enhancement of all type of loss of synchronism and hence reliable tool for low frequency disturbance occurred in power system.
Other Latest Articles
- DESIGNING OF SOLAR POWER SUPPLY SYSTEM FOR DIFFERENT HP MOTORS IN IRRIGATION SYSTEM FOR RURAL AREA OF CHHATTISGARH
- DESIGN OF A LOW POWER CONSUMING SRAM CELL USING MINIMUM TRANSISTORS IN FINFET TECHNOLOGY
- DIY SENSOR BASED CONTROL FOR HYDROPONIC GARDENNING
- FORMALIZATION OF THE PRODUCTION ACTIVITY OF THE CONTAINER COMPANY
- FLEX SENSOR BASED GESTURE CONTROL WHEELCHAIR FOR STROKE AND SCI PATIENTS
Last modified: 2017-05-27 20:32:46