THE COMPARISON OF THE ACCURACY OF MEASUREMENT OF FINAL MOISTURE CONTENT BY DIFFERENT METHODS: HAND-HYGROMETER COMPANY "GANN" AND THE PROXIMITY SENSOR FMI

Journal: Science Journal "NovaInfo" (Vol.1, No. 58)

Publication Date:

Authors : ;

Page : 218-222

Keywords : MOISTURE CONTENT OF LUMBER; HAND ELECTROLASER; PROXIMITY SENSOR; STATISTICAL ANALYSIS; ARITHMETIC MEAN;

Source : Downloadexternal Find it from : Google Scholarexternal

Abstract

Conducted research on the comparison of the accuracy of measurement of final moisture content by different methods: hand-hygrometer company "Cann" and the proximity sensor FMI. The analysis studies based on comparisons of average square errors showed that the accuracy of the measurement of the final moisture contact moisture meter is lower than a moisture meter manual, but as the difference of the errors average final moisture content of the boards is within the allowable range and is 0.5, we can say that both methods give almost the same high measurement accuracy.