Catch per unit efforts and impacts of gears on fish abundance in an oxbow lake ecosystem in Eastern India
Journal: Environmental Health Engineering and Management Journal (Vol.4, No. 3)Publication Date: 2017-10-16
Authors : Dipankar Ghosh Jayanta Kumar Biswas;
Page : 169-175
Keywords : Fish abundance; Fishing gears; CPUE; Oxbow lake;
Abstract
Background: Oxbow lakes are abundant in indigenous fishes, but they are subject to unsustainable fishing practices, potential overexploitation, and indiscriminate use of fine-meshed fishing gear. To quantify the catch per unit effort (CPUE) and impact of fishing gears on fish abundance, a survey was carried out in an oxbow lake in eastern India. Methods: The gear-wise CPUE for fish caught in per unit hour of operation was calculated by dividing the total sampling gear catch in biomass, which is the observed value of fish caught by a particular gear, by the total sampling effort hours. A value of P < 0.05 was accepted as statistical significance. Results: Average annual values of the CPUE of triangular push nets, gill nets, long lines, seine nets, drag nets, stationary dip nets, cone-framed cast nets, and line and hook were calculated as 328.34, 4.12, 36.71, 572.92, 3928.57, 237.78, 235.80, and 0.44 grams of fish per hour of operation, respectively. All the 8 different gears exhibited lower CPUE during monsoon and post-monsoon seasons than in the premonsoon season. The line and hook was dominant (>71%). Cone-framed cast net hauled the maximum catch in biomass (31.51%), and gill nets contributed the maximum number of fish (64.92%). The lower CPUE values of line and hook, gill net, cone-framed cast net and long lines identified them as the most harmful among all gears. Conclusion: Indiscriminate use of gear, particularly line and hook, gill nets, cone-framed cast nets, and long lines, demands regulations and preventions concerning such gear to obtain higher fish abundance.
Other Latest Articles
- An assessment on dispersion of carbon monoxide from acement factory
- Efficiency of electrical coagulation process using aluminum electrodes for municipal wastewater treatment: a case study at Karaj wastewater treatment plant
- Assessment of role of concrete factories in particulate matter emissions, 2015-2016, using the AQI index and zoning by GIS software (Case study: Nasr Kashan Concrete Factory)
- Evaluation the concentration of mercury, zinc, arsenic, lead and cobalt in the Ilam city water supply network and resources
- Estimation of health effects (morbidity and mortality) attributed to PM10 and PM2.5 exposure using an Air Quality model in Bukan city, from 2015-2016 exposure using air quality model
Last modified: 2017-10-16 15:01:15