Development and Validation of Bisacodyl Analysis Method in Tablet with Absorbance Method and Area under Curves Method in Ultraviolet Spectrophotometry
Journal: International Journal of Pharmaceutical Sciences and Medicine (IJPSM) (Vol.2, No. 12)Publication Date: 2017-12-30
Authors : Harrizul Rivai; Nia Pratama; Ridho Asra;
Page : 1-8
Keywords : Bisacodyl; absorbance method; area under the curve method; ultraviolet spectrophotometry;
- Development and Validation of Bisacodyl Analysis Method in Tablet with Absorbance Method and Area under Curves Method in Ultraviolet Spectrophotometry
- Development and Validation of Analysis Methods of Captopril in Tablets with Methods of Area under Curves and Absorbance by Ultraviolet-Visible Spectrophotometry
- METHOD DEVELOPMENT AND VALIDATION OF ROFLUMILAST IN TABLET DOSAGE FORM BY UV SPECTROPHOTOMETRY
- DEVELOPMENT AND VALIDATION OF A NEW ABSORBANCE CORRECTION METHOD FOR ESTIMATION OF TELMISARTAN AND METOPROLOL SUCCINATE IN COMBINED TABLET DOSAGE FORM
- DEVELOPMENT AND VALIDATION OF A UV SPECTROPHOTOMETRIC Q-ABSORBANCE RATIO METHOD FOR SIMULTANEOUS ESTIMATION OF EPERISONE HYDROCHLORIDE AND ACECLOFENAC IN BULK AND TABLET DOSAGE FORM
Abstract
A precise, accurate, fast, and economical simple method has been developed and validated for the analysis of bisacodyl tablets using ultraviolet spectrophotometry with absorbance method and area under the curve. This method is carried out at a maximum absorption wavelength of 263.60 nm and the area under the curve in the range 244.40 - 297.60 nm using a 0.1 N hydrochloric acid solvent. The method of analysis is validated by linearity, detection limits, quantification limits, precision, and accuracy. The linearity of the absorbance method shows the regression equation y = 0.02156x + 0.09258 (r = 0.99963), and the linearity of the wide area method under the curve shows the regression equation y = 0.30618x + 1.17400 (r = 0.99787). Limit detection and quantification limits on the absorbance method 1.411099 and 4.276059, respectively, while the detection and quantification limits on the method of area under the curve 1.968774 and 5.9659197, respectively. Accuracy obtained by the absorbance method and the area under the curve also meet the requirements in the validation of 80 - 120%. The precision obtained by the absorbance method and the area under the curve fulfilled the validated requirement with a yield of RSD ≤ 2%. Statistical analysis was performed by paired sample t test which showed that the two methods did not significantly.
Other Latest Articles
Last modified: 2017-12-04 16:38:08