SPACE VECTOR BASED DECOUPLED PWM TECHNIQUES FOR OPEN END WINDING INDUCTION MOTOR DRIVE
Journal: International Journal of Electrical Engineering and Technology (IJEET) (Vol.8, No. 6)Publication Date: 2017-12-30
Authors : M. RANJIT T. BRAMHANANDA REDDY; M. SURYAKALAVATHI;
Page : 16-28
Keywords : Bus clamping; Common-mode voltage (CMV); Decoupled; Space Vector Modulation; Open-end winding induction motor (OEWIM); Pulse width Modulation(PWM).;
Abstract
In this article, space vector based decoupled bus clamping PWM techniques are proposed for open-end winding induction motor drive (OEWIMD) fed with conventional two level inverters on either side. The switching vectors for the conventional inverters are generated using instantaneous reference voltages along with the simple digital logic. All the proposed bus-clamped PWM techniques are generated by phase shifting the one inverter reference phase voltages by 180 degrees with respect to the other inverter. A common-mode voltage is identified in the OEWIM drive. The entire space vector based decoupled bus –clamping PWM techniques proposed in this work are to reduce the CMV by greater extent and also give less switching loss compared to center spaced space vector PWM technique. The performance of all the proposed decoupled PWM techniques are explored both theoretically and experimentally and the corresponding results are presented.
Other Latest Articles
- AN INNOVATIVE AND ENVIRONMENT FRIENDLY APPROACH TO PRODUCE ELECTRICAL ENERGY UTILIZING HUMAN WASTE ENERGY
- ESTIMATION OF ENERGY PAY-BACK TIME AND AIR POLLUTION MITIGATION POTENTIAL OF A 25-KWP GRID CONNECTED ROOFTOP SOLAR PHOTOVOLTAIC SYSTEM
- DEVELOPMENT OF KNOWLEDGE MINING TECHNIQUES FOR SPATIAL DECISION SUPPORT SYSTEM
- CUSTOMER SEGMENTATION -A CASE OF INCREASE IN CUSTOMER SATISFACTION LEVELS WITH SEGMENT-SPECIFIC CUSTOMER SERVICE STRATEGIES
- MODIFIED DECISION TABLE CLASSIFIER BY USING DECISION SUPPORT AND CONFIDENCE IN ONLINE SHOPPING DATASET
Last modified: 2018-02-08 15:12:39