SAFETY ASSESSMENT OF EXPLOITATION HYDRAULIC STRUCTURES ON THE SMALL RIVER DURING RAIN FLOODS
Journal: BULLETIN OF THE NATIONAL UNIVERSITY OF WATER AND ENVIRONMENTAL ENGINEERING. Technical Sciences (Vol.3, No. 75)Publication Date: 2016-11-09
Authors : Hapich H. V.;
Page : 98-104
Keywords : hydraulic structure; dam; storage reservoir; river;
Abstract
The results of hydrological calculations in the basin on the river Lower Tersа. Determine the maximum flow rate and volume of water rain storm floods. The technical condition of groundwater dams on reservoirs is researched. Survey shows poor condition of spillway facilities. It means the danger of the destruction dams by entering the body of water large quantities of water. Built map and definition of the catchment area of the river Lower Tersа. On the basis of hydrological calculations established structures that sustain breakthrough dams upstream.
Other Latest Articles
- RIVER-BED REGULATION AND ANTI-FLUME DEFENCE AT THE GLOBAL CLIMATE CHANGE CONDITIONS
- INVESTIGATION OF SPECIFIC FLOW ENERGY WITHIN SHARP-CRESTED WEIR
- Green Banking: Perception and Willingness of Customer to Adapt Green Banking
- INFLUENCE OF DRIP IRRIGATION, IRRIGATION WATER QUALITY AND FERTILIZING ON SOIL COMPACTION
- Bacteria and its Good Benefits in Chemical Process Industry Effluents Treatments
Last modified: 2018-03-16 21:45:52