A comparative study to evaluate the effectiveness of timing principle and priming principle for tracheal intubation using rocuronium
Journal: Indian Journal of Clinical Anaesthesia (Vol.4, No. 4)Publication Date: 2017-12-01
Authors : M. Kamalakannan P. Sunder.;
Page : 512-517
Keywords : Rocuronium; Tracheal Intubation; Priming Principle and Timing principle;
Abstract
The present study is to compare the "Timing principle" and the "Priming principle" for tracheal intubation using rocuronium during balanced anesthesia by assessing the Intubating conditions and Hemodynamic changes during intubation. The succinylcholine is considered to be the best drug for rapid tracheal intubation because of its rapid onset and ultrashort duration of the action. The “priming technique” uses a sub-paralyzing dose of non-depolarizing muscle relaxant where 20% of ED 95 or 10% of the intubating dose was administered 2 to 4 min before administering an intubating dose. This technique has been proved to accelerate the onset of action by 30 to 60 seconds.(5) In “timing principle” a single bolus of non-depolarizing muscle relaxant was given followed by the administration of the induction agent after the first sign of the onset of clinical weakness. The “high – dose regimen” was used when tracheal intubation has to be accomplished in less than 60 – 90 seconds.(6) The study was conducted in Madras Medical College, Chennai The groups were comparable based on age and weight. Males were more in Group RP. Using the “Timing principle” with rocuronium 0.6 mg/kg consistently provides good to excellent intubating conditions at 60 seconds after the induction of anesthesia. Using the "Priming principle" with rocuronium 0.06 mg/kg followed by rocuronium 0.54 mg/kg consistently provides fair to good intubating conditions at 60 seconds after induction of anesthesia.
Other Latest Articles
- Comparison of classic laryngeal mask airway with nasogastric tube versus proseal laryngeal mask airway in adults undergoing laparoscopic cholecystectomy
- Comparison of Oxytocin 3IU Bolus + I.V. Infusion 0f 30IU at the Rate of 125 ml/Hr.(0.125 IU/Min.) and oxytocin I.V. infusion at 0.125 IU/Min only, in maintaining uterine tone and hemodynamic stability
- A prospective randomized double blind comparative study of 0.5% ropivacaine and 0.5% bupivacaine in brachial plexus block with supraclavicular approach in upper limb surgeries using peripheral nerve l
- Effect of minimal cuff inflation with thermo softening of the endotracheal tube to minimize the trauma during naso tracheal intubation – observational study
- NEED FOR INFRASTRUCTURE DEVELOPMENT WITH SPECIAL FOCUS ON ECO-TOURISM
Last modified: 2018-04-20 19:00:14