Seismic Performance of RC Structure Using Different Base Isolator
Journal: International Journal of Engineering Sciences & Research Technology (IJESRT) (Vol.3, No. 5)Publication Date: 2014-05-30
Authors : Ashish R. Akhare; Tejas R.Wankhade;
Page : 724-729
Keywords : Base isolation; HDRB; Non-linear time history analysis; SAP2000;
Abstract
Hospital buildings are of great importance after any natural calamity such as earthquake. The structural and non-structural components should remain operational and safe after earthquake. So to mitigate the effect of earthquake on the structure the base isolation technique is the best alternative as a seismic protective system. The basic idea of base isolation system is to reduce the earthquake induced inertia forces by increasing the fundamental period of the structure. The aim of this study is the use of High density rubber bearing (HDRB) and friction pendulum system (FPS) as an isolation device and then to compare various parameters between fixed base condition and base isolated condition by using SAP2000v14 software. In this study the (G+12) storey hospital building is used as a test model.