RELIABILITY IMPROVEMENT OF COOLING WATER PUMP
Journal: International Journal of Mechanical and Production Engineering Research and Development (IJMPERD ) (Vol.8, No. 3)Publication Date: 2018-06-30
Authors : P. YOGESH R. RAGHAVAN R.VIGNESHKUMAR R. HARISH; K. PRAVEENKUMAR;
Page : 755-766
Keywords : Centrifugal Pump; Impeller; Failure Mechanism; Fatigue Failure & Torsional Failure;
Abstract
The project presents an idea of analyzing the stress concentration occurring on the shaft. In the centrifugal pump, there are frequent failures of the shaft during operation, due to which it leads to a breakdown or stoppage of pump working and regular maintenance is conceived. In this project, to recognize the shaft failure, we calculate the load acting on the shaft and forces exerted by the impeller. The stress analysis of the shaft is done by ANSYS software and finally gives suggestions to improve the life of the shaft.