POSSIBILITY OF USING THE CORROSION RATE CONTROL SYSTEM FOR HYDROGEN SULPHIDE ENVIRONMENTS
Journal: Construction, materials science, mechanical engineering (Vol.1, No. 10)Publication Date: 2018-04-13
Authors : USHAKOVA A. V. DOVGALOV L. Y. CHUCHMAN M. R.;
Page : 207-211
Keywords : hydrogen sulphide; corrosion; sensor; electrical resistance;
Abstract
Annotation. Purpose. The determination of the possibility of using the Corrosion rate control system for corrosion rate measurement of carbon steels in hydrogen sulphide environments. Methodology. Corrosion rate monitoring system is based on the electrical resistance method. During the study the data, obtained with the System, was compared with the gravimetric measurement data. Findings. Corrosion rate values, obtained in two independent methods, showed the good convergence. The relative error of corrosion rate measurement by the System was about 3,5 %. Originality. It was found that conductive products of the hydrogen sulphide corrosion do not affect the corrosion rate measurement by electrical resistance method. Practical value. Corrosion rate control system allows to obtain on-line the reliable data about carbon steel corrosion rate in hydrogen sulphide environments continuously and constantly.
Other Latest Articles
- ACCOUNTING OF NATURAL-CLIMATIC FACTORS IN URBAN PLANNING FOR ENSURING LIFE SAFETY
- ELECTRICAL AND VIBRATION IMPACTS REDUCTION FROM RAIL TRANSPORT
- INFLUENCE OF STRUCTURE ON THE CRACK RESISTANCE OF DETONATION SPRAYED CERMET COATINGS
- CRYSTALLIZATION KINETICS AND MICROSTRUCTURE PARAMETERS OF Mg65Cu25Y10 ALLOY, OBTAINED BY QUENCHING FROM THE LIQUID STATE
- PHYSICO-CHEMICAL MODELING OF ATOMIC INTERACTIONS AND OPTIMIZATION OF THE HYPOEUTECTIC SILUMIN AK7CH MICROALLOYING
Last modified: 2018-10-15 08:00:12