OPTIMIZATION OF THE OPERATIONAL PARAMETERS FOR THE FURNACE OF A THREE BED REGENERATIVE OXIDIZER THAT NEUTRILIZES GASEUS POLLUTANTS
Journal: INTERNATIONAL JOURNAL OF ENGINEERING TECHNOLOGIES AND MANAGEMENT RESEARCH (Vol.6, No. 10)Publication Date: 2018-10-30
Authors : Nicholas Pittas Dionissios Margaris Demos P. Georgiou;
Page : 25-34
Keywords : Three Bed Thermal Regenerative Oxidizer; Chemistry of Combustion; Emission Pollutants.;
Abstract
The purpose of this work is to correlate the excess oxidant-air with the percentage of CO2 in the combustion chamber waste gas of a three-bed regenerative thermal oxidizer unit for the elimination of gaseous pollutants in a given capacity.