Performance of electrical stimulated anaerobic baffled reactor for removal of typical pollutants from low-strength municipal wastewater at low temperatures
Journal: Environmental Health Engineering and Management Journal (Vol.6, No. 2)Publication Date: 2019-07-15
Authors : Marziye Moradgholi Mohamadreza Massoudinejad Ehsan Aghayani Ahmadreza Yazdanbakhsh;
Page : 121-128
Keywords : Wastewater; Anaerobic baffled reactor; Electrical stimulated; Treatment;
Abstract
Background: Although anaerobic system has been successfully used for treating the strong industrial wastewater, its efficiency for low-strength wastewater as municipal wastewater is not satisfying. This study aimed to enhance the capability of an anaerobic baffled reactor (ABR) for treating municipal wastewater. Methods: A 7-L ABR with 5 compartments was operated for a 287-day period fed with primary effluent from a wastewater treatment plant at 17 to 19°C. The study was conducted in 2 phases. In the first phase, the performance of ABR and in the second phase, the performance of ESABR (ABR integrated with an electrochemical system) were investigated. Results: The results of ABR operation indicated that at hydraulic retention time (HRT) =24 hours, the average removal efficiency of biochemical oxygen demand (BOD), chemical oxygen demand (COD), total suspended solids (TSS), total Kjeldahl nitrogen (TKN), total phosphorous (TP), and log reduction value (LRV) of coliforms were obtained to be 71%, 75%, 79%, 23%, 30.3%, and 5.8 Log, respectively. In this phase, when the HRT was decreased from 24 to 18 hours and from 18 to 14 hours, the removal efficiency of all parameters by the ABR was decreased. After the shift of ABR operation to ESABR, at HRT=24 hours and current density of 0.78 mA/cm2, the performance of the reactor was enhanced, so that the removal efficiency of BOD, COD, TSS, TKN, TP, and LRV of coliforms were achieved 16.8%, 15%, 4%, 10.7%, 49%, and 1 Log, which was greater than those obtained by ABR. Conclusion: According to the results, this technology (SEABR) is suitable for treating the low-strength municipal wastewater.
Other Latest Articles
- THE ROLE OF THE UN CONVENTIONS AND POLICE AS THE INSTRUMENT OF THE CRIMINAL JUSTICE ADMINISTRATION IN THE PROTECTION OF HUMAN RIGHTS
- Chromium removal and water recycling from electroplating wastewater through direct osmosis: Modeling and optimization by response surface methodology
- Removal efficiency of nitrate, phosphate, fecal and total coliforms by horizontal subsurface flow-constructed wetland from domestic wastewater
- Advanced oxidation of formaldehyde in the aqueous solutions using UVC/S2O82- process: Degradation and mineralization
- Tracking of chloramphenicol, erythromycin, and sulfamethoxazole antibiotic-resistant bacteria from untreated wastewater effluents to receiving river
Last modified: 2019-07-15 14:03:43