ResearchBib Share Your Research, Maximize Your Social Impacts
Sign for Notice Everyday Sign up >> Login

Simulation of 3 Phase, 24 Pulse GTO Converter for Flow Control of Transmission System

Journal: International Journal of Trend in Scientific Research and Development (Vol.3, No. 5)

Publication Date:

Authors : ;

Page : 2158-2163

Keywords : Electrical Engineering; Gate Turn-off Thyristor; Power-semiconductor Devices; Electronic Converter; Voltage Source Converter; Power Flow Controllers;

Source : Downloadexternal Find it from : Google Scholarexternal

Abstract

Gate Turn off GTO thyristor based power control controller for flow control of transmission system is used to regulate voltage and reactive power improment. GTO thyristor switching devices with high power handling capability and the advancement of the other type of power semiconductor devices such as IGBTs, MOSFETs, Ideal switch and so on have led to the development of fast controllable reactive power source utilizing new electronic switching and converter technology. Nowadays, the development of a large capacity Gate Turn off thyristor has made it possible to manufacture self commutated converter employing GTO thyristor for power applications. At present, most of the research on GTO thyristor has focused on their use in power electronic systems at high switching frequencies. GTO thyristor enable the design of the solid state shunt equipment based upon switching technology. The improved rating of GTOs made possible the use of voltage sourced converter VSC in power system applications. In this paper, GTO based voltage source converter VSC is used in high power Flexible AC Transmission Systems FACTS which are used to control power flow on transmission grids. It can be used to build a model of shunt or series static compensator STATCOM or SSSC or, using two such converters, a combination of shunt and series devices known as Unified Power Flow Controller UPFC . This paper has shown a basic application of MATLAB SimPowerSystems programming for 24 pulse GTO converter STATCOM. Zin Wah Aung | Aye Myo Thant | Hnin Yu Lwin "Simulation of 3-Phase, 24 Pulse GTO Converter for Flow Control of Transmission System" Published in International Journal of Trend in Scientific Research and Development (ijtsrd), ISSN: 2456-6470, Volume-3 | Issue-5 , August 2019, URL: https://www.ijtsrd.com/papers/ijtsrd27887.pdfPaper URL: https://www.ijtsrd.com/engineering/electrical-engineering/27887/simulation-of-3-phase-24-pulse-gto-converter-for-flow-control-of-transmission-system/zin-wah-aung

Last modified: 2019-09-10 15:50:33