ESCAPE ROUTE SYSTEMS AT SHOPPING MALLS
Journal: Pozharovzryvobezopastnost/Fire and Explosion Safety (Vol.22, No. 6)Publication Date: 2013-06-29
Authors : SHIKHALEV D. V. Postgraduate Student State Fire Academy of Emercom of Russia KHABIBULIN R. Sh. Candidate of Technical Sciences Docent Associate of Information Technologies Department;
Page : 61-65
Keywords : evacuation; management of evacuation in a burning building; the classification of escape route systems.;
Abstract
Having some specificity, shopping malls have a greater potential fire risk in comparison to other buildings, as a relatively small area is accumulated a large number of people. The first things that needs to be said is one of the most dangerous buildings are shopping malls as buildings with mass of occupants. The analysis of fires in the shopping malls has revealed that the cause of death was including the lack of evacuation systems. The statistical data are analyzed, which show that the ratio of the number of deaths to the number of fires in shopping malls has the stable value. The analysis of statistical data on fires in shopping malls and publications has showed factors contributing to the increase the time of people's evacuation: customers are not aware the evacuation plan, the presence of many people in confined spaces, evacuees were not able to objectively assess the situation, blocking of evacuation routes which have already selected. On the conducted analysis of existing escape route systems the comparative table, which represents the functionality of escape route systems, was developed. Founded on the analysis of existing escape route systems, the classification of these systems was created. It has found that those important function as: prepared algorithms of management of evacuation (47 %), using dynamic indicators (40 %) and mathematical simulation (33 %) were used to less than half of the considered systems. Calculating the number of people and using control sensor were used less than 14 % of the systems.
Other Latest Articles
- MODELING OF TEMPERATURE IN FIRE REGIMES WITH A VIEW OF THE WORK OF EMERGENCY VENTILATION IN PERMEABLE ENVIRONMENT
- INFLUENCE THERMAL INSULATION OF POLYURETHANE FOAM, APPLIED WITH THE INSIDE WALL OF THE VERTICAL STEEL TANK, ON THE TEMPERATURES WALL IN BURNING
- METAMODEL OF SHARED SITUATION AWARENESS FOR RESILIENCE MANAGEMENT OF BUILT ENVIRONMENT WITH HIGH RESPONSIBILITY
- ABOUT INFLUENCE OF NON-DEGRADABLE FILLERS FOR FLAMMABILITY AND SMOKE-FORMING ABILITY OF POLYMER COMPOSITE MATERIALS
- DETERMINATION OF IGNITION KINETIC PARAMETERS FOR DISPERSED CONDENSED SUBSTANCE AT LOCAL HEATING