The Dynamics of Water Ultrafiltration Flow within Framework of Hydrodynamical Approach
Journal: International Journal of Water and Wastewater Treatment (Vol.2, No. 4)Publication Date: 2016-09-05
Authors : Hai-Chao Wang Xiao-Ling Lei Vladimir Olennikov;
Page : 1-3
Keywords : Ultrafiltration; Membrane resistance;
Abstract
The simplest model of adsorbing of fouling for ultrafiltration is considered the simplest model of solutes adsorption and fouling for ultrafiltration was considered. Within framework of hydro dynamical approach the membrane resistance was obtained. The membrane resistance was obtained within a framework of hydrodynamics. It was found that membrane resistance is non-exponential function on membrane operation time. The membrane resistance was found to be a non-exponential function on operation time. We found that for a shot time of membrane operation the flux drops as a linear function. We found the flux drops as a linear function during a short time of membrane operation. For a long time t of operation the flux decline is proportional to t-2.
Other Latest Articles
- Preparation of Bamboo-Based Carbonaceous Adsorbents for the Removal of Musty/Earthy Off-Odors and Vocs
- Long term Wastewater and Biosolids Application in Agriculture
- Treatment of Wastewater from Fish Processing Industry using Chitosan Acid Salts
- Guideline for Disposal of Residues from Wastewater Treatment in Sensitive Mountain Regions
- A Full-Scale Chemical/Biological Treatment System Application for the Wastewater Treatment of a Pharmaceutical-Capsule Production Industry-A Case Study
Last modified: 2020-08-29 00:53:05