Effect of Intra-Abdominal Absorbable Sutures on Surgical Site Infection

Journal: National Journal of Medical Research (Vol.2, No. 3)

Publication Date:

Authors : ;

Page : 371-375

Keywords : Absorbable suture; Surgical site infection; Gastrointestinal surgery;

Source : Downloadexternal Find it from : Google Scholarexternal

Abstract

Purpose: To establish whether the rates of surgical site infection (SSI) in gastrointestinal surgery are affected by the type of intra-abdominal suturing: sutureless, absorbable material (polyglactin: Vicryl), and silk. Methods: We conducted SSI surveillance prospectively in our hospitla. Results: The overall SSI rate was 14.4% (13/90). The SSI rates in the sutureless, Vicryl, and silk groups were 4.8, 14.8, and 16.4%, respectively, without signi?cant differ-ences among the groups. In colorectal surgery, the SSI rate in the Vicryl group was 13.9%, which was signi?cantly lower than that of the silk group (22.4%; P = 0.034). The incidence of deeper SSIs in the Vicryl group, including deep incisional and organ/space SSIs, was signi?cantly lower than that in the silk group (P = 0.04). The SSI rates did not differ among the suture types overall, in gastric surgery, or in appendectomy. Conclusion: Using intra-abdominal absorbable sutures instead of silk sutures may reduce the risk of SSI, but only in colorectal surgery.