CFD Analysis of Single Flow Solar Air Heater with Double ARC Roughness
Journal: International Journal of Science and Research (IJSR) (Vol.9, No. 1)Publication Date: 2020-01-05
Authors : Jitendra Kumar Mishra;
Page : 571-580
Keywords : Rectangular Duct; Double Arc; Nusselt No.;
- Comparative Study of Low Dose Bupivacaine-Fentanyl versus Conventional Dose of Bupivacaine in Spinal Anesthesia for Orthopedic Procedures in Elderly Patients: A Prospective Randomised Double Blind Study
- A comparative study of intrathecal low dose bupivacaine with fentanyl and low dose levobupivacaine with fentanyl in transurethral resection of prostate: Randomized, double blind, prospective study
- A prospective randomised double blind clinical study comparing ropivacaine and fentanyl with bupivacaine and fentanyl for labour epidural analgesia
- DEXMEDETOMIDINE VERSUS FENTANYL WITH INTRATHECAL BUPIVACAINE FOR POSTOPERATIVE ANALGESIA IN UROLOGICAL PROCEDURES: A DOUBLE BLIND COMPARITIVE STUDY
- Comparative Study of Low Dose Vs Regular Dose of Bupivacaine in Patients with Pregnancy Induced Hypertension undergoing Caesarean Section under Spinal Anaesthesia
Abstract
Artificial roughness is used for enhancement of thermal performance of solar air heaters in the form of repeated ribs has been proposed as a convenient method. This thesis presents the CFD investigation of heat transfer and friction factor characteristics of a rectangular duct roughened with repeated Double arc, on one broad wall arranged at an inclination with respect to the flow direction. The duct has a width to height ratio (W/H) of 8, relative roughness pitch (P/e) of 10, relative roughness height (e/Dh) of 0.044, and arc angle of 15?, 30? and 45?. The comparision of heat transfer and friction characteristics of roughened duct and smooth duct under similar flow condition is simulated in this. The effect of change in angle of attack in flow having Reynolds numbers from 2000 to 16,000. The maximum enhancement in Nusselt number and friction factor is observed to be 1.69 and 1.79 times of that of the smooth duct, respectively. The thermo-hydraulic performance parameter is found to be the maximum for the arc angle of 30?.
Other Latest Articles
- New Era in the Drug Delivery System: Formulation and Evaluation of Microsponge of Itraconazole
- A Study on Maternal Risks and Perinatal Outcome of Twin Pregnancy in Tertiary Care Hospital
- Endogenous Strategies to Ending the Nexus between Child Marriage and Teenage Pregnancy in Wa West District, Ghana
- Comparison of Canal Transportation and Remaining Dentin Thickness using Different NiTi Systems with CBCT - An in Vitro Study
- Micro-Grid: Techno-Economic-Greener Solution for Power Distribution System
Last modified: 2021-06-26 19:09:15