An Indoor Experimental Determination of Thermal Efficiency of a Cooking Stove
Journal: International Journal of Science and Research (IJSR) (Vol.8, No. 6)Publication Date: 2019-06-05
Authors : Nathaniel Muwa Shawhatsu;
Page : 424-427
Keywords : water; complete evaporation; liter; stove; temperature; thermal power; parameter and fixed level;
Abstract
Certain mil of water were heated to complete evaporationindoor inside an opening 4 liters cooking pot using a three (3) liters kerosene stove whose wicks were adjusted to a fixed level. On complete evaporation of 50 mL, 75 mL and 100 mL, the internal and external temperature of the pot and time taken were recorded and the measured parameter were used to calculate the quantity and the rate of heat energy supplied by the stove. The quantities of heat calculated for each mil of water evaporated are: 177394 J, 237300 J and 296596 J respectively, while the thermal power supplied by the stove is 664 J/s.
Other Latest Articles
- Study of Prevalence of Diabetic Retinopathy in Diabetics with Microalbuminuria
- Distributed Data Provenance (DDP) to Secure the Sensor Data Stream
- Social Landscape of the Magnitude of Health Care Needs&Barriers in Accessing Health Care among the PLHIV Attended in NGO Clinics of Dhaka City
- Bilateral Rectus Sternalis Muscle: An Anatomical Variant of Anterior Chest Wall
- An Awareness Study about Image Segmentation Methods
Last modified: 2021-06-28 18:17:02