ResearchBib Share Your Research, Maximize Your Social Impacts
Sign for Notice Everyday Sign up >> Login

Slurry Pipe Wear detection by Infrared Thermography: Case of Cyclone Underflow Pipe in Kinsevere Process Copper Plant in Democratic Republic of Congo

Journal: International Journal of Science and Research (IJSR) (Vol.7, No. 5)

Publication Date:

Authors : ; ; ;

Page : 198-201

Keywords : Pipe; wear; infrared; thermography;

Source : Downloadexternal Find it from : Google Scholarexternal

Abstract

This article present the slurry pipes wear detection by using infrared image thermography analysis. By determining via the software the temperature difference on one of pipe area, its possible to determine the wear while the fluid is moving into the pipe. The difference of temperature found on the pipe area makes easily to estimate the wear and suggest the corrective maintenance action. As part of condition monitoring technics, this is helpful to contribute to pipes thickness monitoring.

Last modified: 2021-06-28 19:12:09