RP-HPLC Method Development and Validation for the Analyisis of Pharmaceutical Drug ? ACECLOFENAC
Journal: International Journal of Science and Research (IJSR) (Vol.6, No. 7)Publication Date: 2017-07-05
Authors : Ami R Patel; V G Patel;
Page : 1318-1320
Keywords : Aceclofenac; Method Development; Validation; 210nm; 30min;
Abstract
A simple, selective, linear, precise and accurate RP-HPLC method was developed and validated for rapid assay of ACECLOFENAC. Isocratic elution at a flow rate of 1.2 ml /min was employed on a symmetry C18 column at ambient temperature. The mobile phase consisted of Acetonitrile 0.1M Acetic Acid 6040 (v/v). The UV detection wavelength was at 210 nm. Linearity was observed in concentration range of 0.01-0.05 gm/ml. The retention time for ACECLOFENAC was 3.0 min. The method was validated as per the ICH guidelines. The proposed method can be successfully applied for the estimation of ACECLOENAC.
Other Latest Articles
- Diversity, Abundance and Interspecific Correlation in Water-Birds at Anasagar Lake, Ajmer
- Image Localization Using Google Maps
- Satellite Image Enhancement for Fusion of Multispectral and Panchromatic Images
- Evaluation of Water Quality using Bhargava Water Quality Index Method and GIS, Case Study: Euphrates River in Al-Najaf City
- Soil Organic Carbon Stock in Natural and Human Impacted Ecosystems of Senapati District, Manipur