Analysis of a Combined Absorption Cycle for Power and Cooling with R134a-DEGDME Working Fluid Using a Scroll Expander
Journal: International Journal of Science and Research (IJSR) (Vol.3, No. 5)Publication Date: 2014-05-15
Authors : James Muye; Joan Carles Bruno; Rajagopal Saravanan; Alberto Coronas;
Page : 412-417
Keywords : Absorption cycles; Expander; Scroll; Power and coolingR134a/DEGDME mixture;
Abstract
This paper presents the integration of a scroll expander into a combined power and cooling absorption cycle driven by low-grade heat sources such as solar energy and waste heat. R134a-DEGDME has been selected as the working fluid mixture to replace the commonly used ammonia-water mixture. The scroll device used here is derived from a compressor. The mathematical model adopted for the expander incorporates a simplified semi-empirical model that calculates the mechanical power, exhaust temperature and supply mass flow rate of the expander at accuracy levels of 9 %, 2 K and 3 %, respectively. Some operating parameters such as the generator (90-100C), condenser (18-26C) and evaporator (-4-10C) temperatures have been varied to investigate the behaviour of the combined cycle. For the selected cycle it is suggested that increasing the generator temperature is beneficial to both power generation and cooling production. However, increasing the condenser temperature is detrimental for both power and cooling. The increase of the evaporator temperature is also favorable for both outputs.
Other Latest Articles
- Feasibility Study of Solar Power Plant for Pondicherry University
- Investigation of Performance and Power Quality of Grid-Connected Solar PV System
- Seasonal Variations of Children's Personal Exposure to Ultrafine Particles in Different Microenvironments in Bhutan
- Performance Simulation of Residential Building Envelope with Real Environment in Thimphu, The Capital City of Bhutan
- Analysis on Integrated LPG Cook Stove and Induction Cooktop for Cooking Purposes in Bhutan
Last modified: 2021-06-30 19:59:36