Neutron dose evaluation of Elekta Linac at two energies (10 & 18 MV) by MCNP code and comparison with experimental measurements
Journal: Journal of Advances in Physics (Vol.6, No. 1)Publication Date: 2014-10-16
Authors : Negin Shagholi; Hassan Ali; Mahdi Sadeghi; Arjang Shahvar; Hoda Darestani; Banaee Nooshin; Kheirolah Mohammadi;
Page : 1006-1015
Keywords : Neutron; TLD600; TLD700; dosimetry; Monte Carlo;
Abstract
Medical linear accelerators, besides the clinically high energy electron and photon beams, produce other secondary particles such as neutrons which escalate the delivered dose. In this study the neutron dose at 10 and 18MV Elekta linac was obtained by using TLD600 and TLD700 as well as Monte Carlo simulation. For neutron dose assessment in 2020 cm2 field, TLDs were calibrated at first. Gamma calibration was performed with 10 and 18 MV linac and neutron calibration was done with 241Am-Be neutron source. For simulation, MCNPX code was used then calculated neutron dose equivalent was compared with measurement data. Neutron dose equivalent at 18 MV was measured by using TLDs on the phantom surface and depths of 1, 2, 3.3, 4, 5 and 6 cm. Neutron dose at depths of less than 3.3cm was zero and maximized at the depth of 4 cm (44.39 mSvGy-1), whereas calculation resulted in the maximum of 2.32 mSvGy-1 at the same depth. Neutron dose at 10 MV was measured by using TLDs on the phantom surface and depths of 1, 2, 2.5, 3.3, 4 and 5 cm. No photoneutron dose was observed at depths of less than 3.3cm and the maximum was at 4cm equal to 5.44mSvGy-1, however, the calculated data showed the maximum of 0.077mSvGy-1 at the same depth. The comparison between measured photo neutron dose and calculated data along the beam axis in different depths, shows that the measurement data were much more than the calculated data, so it seems that TLD600 and TLD700 pairs are not suitable dosimeters for neutron dosimetry in linac central axis due to high photon flux, whereas MCNPX Monte Carlo techniques still remain a valuable tool for photonuclear dose studies.
Other Latest Articles
- First application of total skin electron beam therapy for Mycosis Fungoids in Iran
- 1.3mW 1550nm Er-DOPED SUPER FLUORESCENT FIBER SOURCE FOR MISSILE FIBER OPTICS GYROSCOPE
- TEMPERATURE DEPENDENCE BEHAVIOR OF ELECTRICAL RESISTIVITY IN NOBLE METALS AT LOW TEMPERATURES
- The build of nonlinear quantum mechancs and variations of feature of microscopic particles as well as their experimental affirmation
- Mixed convection flow due to a moving vertical plate parallel to free stream under the influence of Newtonian heating and thermal radiation
Last modified: 2015-01-16 20:18:41