Leakage Current Test at Household Refrigerator Type Urg-129 Base Standard Nasional Indonesia (Sni) 04-6292.2.24-2001 For Safety Equipment

Journal: Asian Journal of Natural and Applied Sciences (Vol.3, No. 4)

Publication Date:

Authors : ; ; ; ;

Page : 23-34

Keywords : Leakage Current Test; Refrigerator; Electrical Safety Test; Uncertainty.;

Source : Downloadexternal Find it from : Google Scholarexternal

Abstract

Leakage current testing is one of the types of electrical safety test, where test is intended to determine the level of security of an electronic product in this refrigerator URG - 129. Testing is done by giving some different behavior to the test specimen, ranging from varying the loading rate and the value of the input voltage be changed. To then measured the value of electric current leaking from the installation of ground or body surface of the test specimen. From the analysis of the leakage current values obtained under full load with input voltage of 245 Volts PLN, for earth leakage line ( normal ) ( 2458 ± 0335 ) mA, earth leakage line ( single fault) ( 4.0983 ± 0338 ) mA, Touch Chassis ( single fault ) ( 2.485 ± 0.334 ) am. Based on the value of leakage current, then the refrigerator Uchida URG - 129 is expressed not meet the requirements as specified in ISO 04-6292.2.24-2001.