Optimization of Base Frame of Multistage Centrifugal Pump maintaining the Shaft Deflection as per API Standards
Journal: International Journal of Science and Research (IJSR) (Vol.4, No. 9)Publication Date: 2015-09-05
Authors : Mayuri M. Choundikar; V. J. Khot;
Page : 1348-1351
Keywords : Multistage Centrifugal Pump; Base Frame; Motor; Shaft Deflection; API Standards;
Abstract
Base Frame are the traditional and most common means for reducing weight of pump. The factor of safety of existing base frame is more than the required. In this project work, after optimizing weight of base frame of multistage centrifugal pump the factor of safety reduces and it becomes as per required. For weight reduction we considered the forces and moments acting on the suction and discharge nozzle of the pump. Shaft deflection analysis is carried out by using ANSYS software. Also the shaft deflection of pump is checked after optimization which is within API 610 standard.