Journal: International Journal of Science and Research (IJSR) (Vol.5, No. 7)

Publication Date:

Authors : ;

Page : 947-950

Keywords : Exterior beam column joint; lateral loads; STAADPro V8i; NX CAD; ANSYS;

Source : Downloadexternal Find it from : Google Scholarexternal

Abstract

In a multi-storied building, the beam-column joint is one of the most critical regions. Usually the beam-column joint was considered as rigid frames. Various researchers over the past years indicated that the joint is not rigid. Now it is also stated that instead of the failure in beam and column, failure can also occur in joint, hence joint must be considered as a structural member. The Indian standards define a joint as the portion of the column within the depth of the deepest beam that frames into the column. In framed structures the bending moment and shear forces are maximum at the junction area. So, beam column joint is one of the failure zones. Among the beam column joints, the exterior joint is more critical. The exterior beam column joint have been a study for about 30 years since now. Still there are many more to be understood. In the present work a building is designed in STAAD. Pro V8i and an exterior beam column joint is considered. This joint is modelled in NX CAD and imported to ANSYS to analyse it to derive the shear stress and the corresponding deformation.