ResearchBib Share Your Research, Maximize Your Social Impacts
Sign for Notice Everyday Sign up >> Login

Simultaneous Determination and Validation of Olmesartan Medoximil and Metoprolol Tartarate by Analytical Technique RP-HPLC

Journal: International Journal of Science and Research (IJSR) (Vol.5, No. 8)

Publication Date:

Authors : ; ; ;

Page : 1557-1561

Keywords : ICH; Validation; Olmesartan Medoximil; Metaprolol Tartarate; RP-HPLC;

Source : Downloadexternal Find it from : Google Scholarexternal

Abstract

A rapid reverse phase high performance liquid chromatography method has been developed and validated for the determination of Olmesartan medoximil and metaprolol tartarate in combined tablet dosage form. Isocratic technique was adopted using C18 column (1504.6mm, 5 XTerra) with a phosphate buffer [pH 2.8] as a mobile phase and the flow rate of 0.5ml/min at UV wavelength 284nm. The Rt values was found to be 3.624 & 5.178min and the above drugs with a run time of 10min. Various chromatographic parameters including Specificity, Linearity, Accuracy, Precision, LOQ, LOD, Robustness, System suitability have been evaluated. The present investigation was validated as per ICH guidelines for the drugs.

Last modified: 2021-07-01 14:42:41