NEW METHOD OF SIZING A FILTER (RL-C) FOR AN INVERTER WITH SPWM CONTROL IN MEDIUM VOLTAGE ALTERNATING

Journal: International Journal of Advanced Research (Vol.9, No. 04)

Publication Date:

Authors : ; ;

Page : 34-43

Keywords : Filters (L-C) and (RL-C) Inverter with SPWM Control THD MATLAB-SIMULINK Quality Factor Q RMS Value RMS Fundamental Value;

Source : Downloadexternal Find it from : Google Scholarexternal

Abstract

The need to use SPWM controlled voltage inverters in MV, led us to examine how to filter alternative signals with filters (L-C) and (RL-C). This allowed us to decide on the use of certain formulas for calculating the elements of these filters. Likewise, we have proposed a method of calculating the resistance R by mathematical iterations without using the quality factor Q, in order to obtain a low error rate between the RMS values and the fundamental effective values and THDs respecting the standard 519 IEEE - 2014. The results of these studies obtained using the MATLAB-SIMULINK software are presented in the penultimate session of this article. Nomenclature SPWM Sinusoidal Pulse-Width-Modulation THD Total Harmonic distortion SN Apparent power of the alternating load MV Medium voltage alternating voltage (1 kV --- 50 kV) Uph phase-to-phase voltage at the ac load RMS Root Mean Squared R L C Resistance Inductance Capacitor MVDC Medium voltage direct current VSI Voltage Source Inverter

Last modified: 2021-08-06 20:39:54