A Study on Repeatability and Agreement of Keratometry & Refractive Prediction between Verion and IOL Master
Journal: International Journal of Science and Research (IJSR) (Vol.10, No. 9)Publication Date: 2021-09-05
Authors : Kaksha Desai; Riddhi Shah;
Page : 682-686
Keywords : VERION planner; IOL master 500; cataract; IOL power; K reading; post - operative spherical outcome;
Abstract
Purpose: The aimed to analyse the predictability of the instrument for calculation of IOL power and K reading on VERION planner and to check the verion predicted refractive power or final follow - up refractive power. Methodology: From March 2020 to July2021, a retrospective investigation was done at the Rotary Eye Institute in Navsari. The study included 120 eyes, both preoperatively and postoperatively, from people who had cataract surgery (phacoemulsification). The patients were assessed on both machines by the same examiner during each individual pre - assessment, and then followed up on the VERION image - guided system as well as the IOL master roughly 2 months after surgery by the same examiner. The calculation for the predictive spherical outcomes for both the IOL Master and VERION systems. Then both IOL Master IOL power and verion IOL power and the VERION Predicted refractive power and after final follow up refractive power were compared using SPSS software. Result: Pre - operative IOL K1 (43.42 ? 1.94) was almost same significantly (pless than0.01) VERION K1 value (43.42 ? 1.94). Pre - operative IOL K2 (43.31 ? 2.07) was significantly same as the VERION K2 (43.40 ? 2.07). Pre - operative VERION predicted refractive status (SPH & CYL) in 2.2mm incision ( - 0.15 ? 0.12) ( - 0.70 ? 0.54) was decreases (- 0.04 ? 0.20) (- 0.49 ? 0.60) significantly after Final follow - up. Pre - operative VERION predicted refractive status (SPH & CYL) in 2.8mm incision (- 0.18 ? 0.11) (- 0.93 ? 0.56) was decreases ( - 0.07 ? 0.21) ( - 0.88 ? 0.96) significantly after Final follow - up. Pre - operative VERION predicted refractive status (SPH & CYL) in 3.0mm incision (- 0.17 ? 0.10) (- 0.76 ? 0.54) was decreases (-0.13 ? 0.33) (- 0.88 ? 0.96) significantly after Final follow - up. The correlation between two (IOL master 500 & VERION) for determining pre - operative keratometry reading demonstrated a high relationship between the pre - operative K1 of IOL master & VERION (pless than0.01, r=0.975) and pre - operative K2 of IOL master & VERION (pless than0.01, r=0.981). The correlation between (IOL master, VERION and IOL implanted power) demonstrated a medium relationship between the IOL master power and VERION power (pless than0.01, r=0.679) & a high relationship between the IOL master and IOL implanted power (pless than0.01, r=0.954) & a high relationship between the VERION and IOL implanted power (pless than0.01, r=0.748). Conclusion: After the two months final follow - up the Sph and Cyl power are decreased then the VERION predicted refractive power but the cylinder power was almost same as the VERION predicted power. The analysis suggests that there was a statistically correlation between IOL master and VERION.
Other Latest Articles
- Phytochemical Analyses of a Few Neglected and Underutilized Fruit Vegetables of Cucurbitaceae
- Crowd Dynamics: A Tool in Shaping Urban Spaces
- Mahua Oil as Renewable Resources for Biodiesel Production: Indian Perspective
- Laboratory Examination SARS Cov2
- Digital Fashion Market Practices and Needs during COVID19
Last modified: 2022-02-15 18:43:29