ResearchBib Share Your Research, Maximize Your Social Impacts
Sign for Notice Everyday Sign up >> Login

Comparative Analysis and Design of Voided Slab and RCC I Girder with Solid Slab in Bridge Structure

Journal: International Journal of Trend in Scientific Research and Development (Vol.5, No. 6)

Publication Date:

Authors : ;

Page : 1567-1580

Keywords : Voided Slab; RCC Girder; Solid Slab; STAADpro Concrete; Reinforcement; Bridge deck;

Source : Downloadexternal Find it from : Google Scholarexternal

Abstract

This thesis is basically based on the comparison of the use of voided slab, RCC Solid slab and RCC Girder. In this study analysis and cost comparison of RCC Solid slab deck, RCC Voided slab deck and RCC Girder is done for superstructure spanning 20 m length. Solid slabs having greater span are uneconomical due to heavy dead load of concrete. To make it economical longitudinal beams are provided for spans greater than 10.0 m. Reinforced Concrete Girder is generally adopted for a fly over or road bridge, but in case of a river bridge with submersible superstructure, the longitudinal beams creates obstruction to the flow of water and results in additional stresses in cross direction on beams. To reduce the self weight of concrete without sacrificing its flexural strength, in solid slab voids are incorporated in concrete section. This technic offers many advantages over a conventional solid concrete slab like reduced material use, lower total cost of construction, and increased structural efficiency. This report also shows that the dead load of bridge superstructure can be reduced by providing voids in concrete where it is unnecessarily provided. Presence of voids within the concrete structure makes analysis of structure very complicated. The analysis of RCC Solid slab, RCC Girder and RCC voided slab deck for various loads as specified in IRC is done using staad pro software for span length of 20 m and width of 15.10 m. The analysis illustrates the behavior of bending moments, Shear Force, displacements, reactions for various load conditions. It is concluded that use of voided slab is more feasible for 20 m length and 15.10 m width. It is also economical as compared to solid slab and Reinforced concrete Girder. Kunal Songra | M. C. Paliwal "Comparative Analysis and Design of Voided Slab and RCC I Girder with Solid Slab in Bridge Structure" Published in International Journal of Trend in Scientific Research and Development (ijtsrd), ISSN: 2456-6470, Volume-5 | Issue-6 , October 2021, URL: https://www.ijtsrd.com/papers/ijtsrd47679.pdf Paper URL : https://www.ijtsrd.com/engineering/civil-engineering/47679/comparative-analysis-and-design-of-voided-slab-and-rcc-i-girder-with-solid-slab-in-bridge-structure/kunal-songra

Last modified: 2022-03-01 14:04:49