Gain-scheduled linear-quadratic-regulator synthesis for the centre of gravity variations of Boeing 747-100 longitudinal modes
Journal: International Journal of Advanced Technology and Engineering Exploration (IJATEE) (Vol.9, No. 92)Publication Date: 2022-07-30
Authors : Ezzeddin M. Elarbi Dina S. Laila; Nadjim M. Horri;
Page : 868-887
Keywords : Boeing 747-100 flight envelope; Tracking longitudinal modes; Elevator and throttle coupling; Centre of gravity variation; Linear quadratic regulator; Gain scheduling; Cubic spline.;
Abstract
For the variation in the centre of gravity (CG) of Boeing 747-100 (B747-100) longitudinal flight, the gain scheduling (GS) method is proposed to manage it over the flight envelope. The full-state feedback linear quadratic regulator (FSFLQR) has been synthesised with the GS, named (GS-FSFLQR), to obtain a realistic controller for Mach numbers (M) and altitudes (H) envelope. Such a practised control law demonstrates the CG mean aerodynamic chord (MAC) shifts correlated with M-H and actuator actions. The intermediate variable responses have been accomplished at (M, H) simulations of (0.2, 0), (0.5, 6096 m) and (0.9, 12190 m). Local controllers at M and H scheduled parameters are gained using the cubic spline method of 0.2 to 0.9 and sea level to 12190 m. Swift levelled convergences illustrated the B747-100 CG variations throughout most responses for a coupled elevator and throttle-controlled flight. These findings are validated for the flying quality requirements showing the competent merits of the GS-FSFLQR as opposed to without control flight. The maximum elevator capacity transmits the CG from the 17% MAC at (0.3, 6096 m) to 30% MAC at (0.7, 3048 m), whereas the maximum throttle occurs for the CG at 25% MAC at (0.5, 6096 m). Their minimum operations lead to 22% MAC at (0.6, sea level). The dominated CG location of the elevator is fore than 25% MAC whereas the aft and fore locations of the throttle float around that. 50% actuator effectiveness due to operable elevator and throttle adequately copes with the CG longitudinal stability.
Other Latest Articles
- Post-Harvest Interventions to Extend the Shelf Life and Maintain the Quality of Indian Jujube CV. Umran 29 Under Ambient Storage Conditions
- Harnessing solar energy during preferential tripping to supply non-essential loads in luxury vessels
- Remote Sensing and GIS for Wastelands and Land Utilisation Studies of Periya Kalrayan Hill, Salem and Vellupuram District
- Reasons of Farmers Suicide in Jayshankar Bhupalpally District of Telangana State
- Water Quality Assessment of Water Treatment Plants Used in Kandhari Beverages Pvt. Ltd. Samba, Jammu and Kashmir, India
Last modified: 2022-09-10 18:19:34