Current requirements to designing fire protection systems for educational establishments

Journal: Pozharovzryvobezopastnost/Fire and Explosion Safety (Vol.31, No. 2)

Publication Date:

Authors : ;

Page : 5-14

Keywords : fire truck driveways; fire separation distances; evacuation; fire risk; rescue; allowable building height; allowable floor for premises; fire resistance limit; fire hazard class; floor area; fire compartment;

Source : Download Find it from : Google Scholarexternal

Abstract

Introduction. It is necessary to update requirements for designing fire protection systems for these facilities in terms of the safe evacuation and rescue of children and personnel, increase the efficiency of fire emergency response units conducting rescue operations, as well as optimize space planning and structural solutions to ensure a high level of fire safety inside buildings of preschool and general education organizations. Goals and objectives. The purpose of the article is to validate the updated requirements for designing fire protection systems for buildings of preschool and general education organizations in compliance with the Federal Law of the Russian Federation dated July 22, 2008 № 123-FZ «Technical regulations governing fire safety requirements» (hereinafter – «№Law 123-FZ»). Methods. An analytical method is used to formulate and substantiate the requirements for designing fire protection systems for educational establishments within the framework of the integrated application of Law 123-FZ and with regard for current trends in architecture and structural design of similar buildings, as well as fire risk calculations. Results. The results of the work are contributed to the amended sets of effective fire safety rules, such as SP 1.13130.2020 «Fire protection systems. Evacuation routes and exits», SP 2.13130.2020 «Fire protection systems. The fire resistance of protected facilities», SP 4.13130.2013 «Fire protection systems. Restricting fire spread throughout protected facilities. Requirements for space planning and structural solutions» (Amendment 1), etc., as well as SP 251.1325800.2016 «Buildings of general education organizations. Design rules» (Amendment 3). Conclusion. The research findings were employed to substantiate the current requirements for designing fire protection systems for educational establishments to improve the safety of children in the process of evacuation and rescue, if these buildings have premises featuring various classes of functional fire hazard, fire resistance limits and fire hazard classes of building structures, building materials and engineering installations.

Last modified: 2023-03-01 02:33:45