CONTROL OF MAGNETISATION AND DEMAGNETISATION IN INDUCTION MOTOR VECTOR CONTROL SYSTEMS
Journal: Electromechanical and energy saving systems (Vol.3, No. 15)Publication Date: 2011-09-30
Authors : O. Tolochko; P. Rozkaryaka; G. Chekavsky; A. Kugel;
Page : 79-82
Keywords : asynchronous motor; vector field-oriented control; flux control; energy losses decreasing.;
Abstract
Analysis of heat losses in pauses at short-time mode of field-oriented controlled asynchronous motor has been car-ried out. Expressions and graphics have been examined, they let make a right decision about appropriateness of rotor flux control or its holding at a constant nominal level in pauses, depends on necessity of decreasing of heat losses in motor’s windings.