ResearchBib Share Your Research, Maximize Your Social Impacts
Sign for Notice Everyday Sign up >> Login

INFLUENCE THE START-UP PUMP ELECTRIC DRIVE PARAMETERS ON PRESSURE IN THE WATER SUPPLY SYSTEM AS LINES WITH THE DISTRIBUTED PARAMETERS

Journal: Electromechanical and energy saving systems (Vol.3, No. 19)

Publication Date:

Authors : ; ;

Page : 202-204

Keywords : hydraulic blow; pump unit; pressure increase.;

Source : Downloadexternal Find it from : Google Scholarexternal

Abstract

In article it is shown that at start-up of pumps electric drives there is an essential increase of pressure in water supply systems. It is caused by wave processes in a water supply system as lines with the distributed parameters. This phenomenon can cause frequent rushes in networks at their deterioration. It is shown how means of the electric drive it is possible to reduce pressure amplitude in a water supply system depending on its extent.