NEW CYCLE OF AVERAGE PRESSURE FOR AIR LIQUEFYING AND POSSIBILITY OF ITS APPLICATION IN VRU
Journal: REFRIGERATION ENGINEERING AND TECHNOLOGY (Vol.51, No. 3)Publication Date: 2015-06-25
Authors : М.B. Kravchenko;
Page : 90-97
Keywords : cryogenic engineering; thermodynamic losses; air fractionation.;
Abstract
The new cycle of average pressure for air liquefaction permitting lowering of thermodynamic losses in heat exchange devices is offered. On specific examples with application of the q-1/T diagrams analysis and comparison of thermodynamic losses in a classical Clothe cycle, in air separation units cycle and offered cycle is carried out. The opportunity to use offered cycle in air separation units for obtaining the liquid components of air fractionation is considered.
Other Latest Articles
- EXPERIMENTAL STUDIES OF CAPABILITIES FOR ENHANCEMENT OF VAPORIZA-TION HEAT TRANSFER AT THE MICROCHANNEL SURFACES
- NUMERICAL SIMULATION OF TEMPERATURE SEPARATION IN METHANE STREAM IN RANQUE-HILSCH VORTEX TUBE
- THE NANOPARTICLES EFFECT ON THE LIQUID-LIQUID PHASE EQUILIBRIUM PARAMETERS. PART 2
- ANALYSIS OF PROSPECTS FOR USE ON VESSELS PUMPLESS ABSORPTION-TYPE REFRIGERATING UNITS
- GENERATION OF HEAT FLUX NEAR THE CAPILLARY IMMERSED INTO THE CAVITATING LIQUID DUE TO THE EXTERNAL ACOUSTICAL FIELD
Last modified: 2015-07-08 05:32:22