An evaluation of bacteriological quality of drinking water from the catchment area of a tertiary care teaching hospital
Journal: International Archives of Integrated Medicine (IAIM) (Vol.2, No. 7)Publication Date: 2015-07-15
Authors : Shamsi MS; Goel S; Singh A; Gupta A; Mirza RUB; Jai Krishna; Bharat M; Chitti Babu G; Singh AK; Surana A;
Page : 78-81
Keywords : Drinking water; Bacteriological quality; Culture.;
Abstract
Background: It is well-appreciated that many communities in developing countries face severe public-health problems relating to drinking-water. The supply of safe water is important to protect the health of the community people. Aim: The study aimed to evaluate the bacteriological quality of drinking water from various active sources of water utilized in the catchment area of a tertiary care teaching hospital. Material and methods: The present cross sectional study was carried out by the Department of Microbiology and Community Medicine, MSDS Medical College, Fatehgarh during 2013-14. Randomly selected 100 active water sources which were being used for drinking purpose and a fairly good number of people using that water source for drinking purpose were included in the study. National Environmental Engineering Research Institute (NEERI) guidelines for drinking water quality assessment were adopted. Culture and bacteriological tests of drinking water were performed as per standard protocols. After compilation of collected data, analysis was done using Statistical Package for Social Sciences, version 21 (IBM, Chicago, USA). Results: Out of one hundred water samples collected, fifty one, twenty seven and twenty two samples of water were collected from municipal tap water, government hand pump and water cooler respectively. Almost half of the samples were found to be unsatisfactory. E. coli was found to be responsible for 26% of samples whereas Pseudomonas in 20% of collected samples. E. coli and Klebsiella tested positive with Methyl Red whereas Pseudomonas sp. and Klebsiella tested positive with Citrate test reagent. E. coli showed positive result with Indole reagent whereas Klebsiella tested positive with Urease. Regarding mix population organisms, Escherichia coli, Klebsiella Sp. and Pseudomonas Sp. were found to be positive in 3 samples whereas Klebsiella Sp. and Pseudomonas Sp. were found to be positive only in 1 sample. Conclusion: The study highlighted unsafe nature of current active sources in the study area with regard to drinking water purpose which are not fit for consumption of water. Surveillance of water sources and regular bacteriological assessment of all water sources for drinking is recommended on regular basis.
Other Latest Articles
- Clinico-pathological correlation of patients undergoing keratoplasty for suspected HSV keratitis in tertiary care centre
- Inverse Iterative Methods for Solving Nonlinear Equations
- Radiographic analysis of thyroid lesions using USG and CT scan
- Histological differentiation of human fetal kidney
- Secondary hyperparathyroidism in chronic kidney disease
Last modified: 2015-07-16 19:53:09