Dynamic response property of cooling tower structures
Journal: Challenge Journal of Structural Mechanics (Vol.1, No. 1)Publication Date: 2015-04-24
Authors : Takashi Hara;
Page : 38-41
Keywords : cooling tower; R/C shell; column support; finite element method; parallel processing; dynamic response;
Abstract
Reinforced concrete (R/C) cooling tower structures have been used for cooling down the hot water produced by power or chemical plants. These structures are designed to prevent against the failure under a self-weight and a wind loading, as well as an earthquake loading. In this paper, the numerical scheme under parallel processing is introduced and the dynamic evaluation of the cooling tower under an earthquake loading is examined. In numerical analyses, the cooling tower is assumed to have two types of conventional column system, i.e., V-column and I-column systems. Both R/C shell portion and column system are modeled by use of solid elements. From the numerical analyses, the higher stress concentrations are arisen between the junctions of R/C shell and columns for I-column than those for V-column. Also, it is concluded that the additional reinforcements should be placed around the junction considering the seismic effects.
Other Latest Articles
- Seismic behavior analysis of multi-story reinforced concrete buildings having torsional irregularity
- Earthquake design of a viaduct with full seismic isolation of bridge deck
- Seismic analysis of interlocking mortarless hollow block
- A modified member stiffness procedure for dynamic progressive collapse analysis of planar frames
- An experimental study on influence of shear failure type partial wall on reinforced concrete frame
Last modified: 2015-09-13 23:21:39