C-V Characteristic of (PbO)1-x (CdO)x/p-Si Heterojunction Prepared by Spray Pyrolysis Technique
Journal: International Journal of Application or Innovation in Engineering & Management (IJAIEM) (Vol.4, No. 8)Publication Date: 2015-09-15
Authors : Nahida B. Hassan; Mohammed Ahmed Mohammed;
Page : 75-79
Keywords : Keywords: Pergamum Harmala; concentration of activity; medium and heavy elements; HPGe gamma-ray spectroscopy; X-ray fluorescence spectrometer analysis;
- Speech Intelligibility Enhancement in the context of Hearing -Impairment
- REMEDIAL TEACHING WORK ON THE DEVELOPMENT OF COHERENT SPEECH IN STUDENTS WITH HEARING IMPAIRMENT
- Assessment of Quality of Life and Problems Faced by the Mothers of Children with Hearing and Speech Impairment attending Selected Special Schools, West Bengal
- EVALUATION OF SOUND CLASSIFICATION USING MODIFIED CLASSIFIER AND SPEECH ENHANCEMENT USING ICA ALGORITHM FOR HEARING AID APPLICATION
- Psychophysiological Models Sensation and Perception of Speech Signals: in what Intelligibility Difference
Abstract
ABSTRACT The concentrations of naturallyradioactive occurring and technically enhanced radioisotopes of 10 samples of Peganumharmala insecular equilibrium, collected from different markets in province of Baghdad, have been investigated; using HPGegamma-ray spectroscopy established at low background configuration. Also, the activity concentrations of 40K (1460.81 keV ), 75Se (96.73keV ), 85Kr (513.99 keV), 88Y (1836.01 keV) and 134Cs (563.23 keV, 801.93 keV and 1167.94 keV ) are determined. The average Activity concentrations of the radio elements 40K,75Se, 85Kr and 134Cs in Peganumharmala samples are found to be 425±12.22, 350±10.05, 304±8.73 and 159.17±4.57 Bq/kg respectively, which are below the international global limits. Apparently, the traces of different medium and heavy elements have been investigated using the X-ray fluorescence spectrometer analysis. The measures show the dominant of Potassium-K element in PM samples with the average concentration obtained 53652.62ppm. The other measured traces of the elements indicate a decreasing in the order of K>Fe>Ti>Zr>Nb>Sr>Y>Zn>Ga for the PM samples rather than the order mentioned in reference [37].
Other Latest Articles
- DETECTION OF OPTIMAL PATH USING QUADRATIC ASSIGMENT TECHNIQUE IN WIRELESS SENSOR NETWORKS
- 3D Mapping of Hazardous Airborne Dusts Adversely Affecting Air/Ground Transportation, Health and Environment Using Unmanned Aerial Vehicle Northern Saudi Arabia
- The concentrations of Natural Radioactivity in Pergamum Harmala Seeds
- A Binary Multi-Objective Genetic Algorithm & PSO involving Supply Chain Inventory Optimization with Shortages, inflation
- Signature Recognition and Verification: The Most Acceptable Biometrics for Security
Last modified: 2015-09-15 14:54:01