Monte Carlo investigation of prostate cancer ion ? therapy by using SOBP technique in the GEANT4 toolkit and MCNPX code

Journal: Journal of Advances in Physics (Vol.8, No. 2)

Publication Date:

Authors : ; ; ;

Page : 2078-2083

Keywords : investigation;

Source : Downloadexternal Find it from : Google Scholarexternal

Abstract

Regarding the useful results concerned with an external radio-therapy in treatment of tumors, we consider in this paper a standard model of the human prostate phantom based on MIRD phantom for the Monte Carlo simulation in GEANT4 toolkit and also on MCNPX code for a prostate cancer treatment. We calculate the lateral as well as the dose profiles in the tumor region for both proton and alpha beams in a similar range, and finally having implemented the SOBP technique, we compare the results of the two beams in the corresponding codes used in this analysis.