A Study on the Efficiency when replacing SSR Dimmer with IGBT SINEWAVE Dimmer in Concert Halls
Journal: The Journal of the Institute of Internet, Broadcasting and Communication (Vol.15, No. 3)Publication Date: 2015-06-30
Authors : Jang-Weon Lee; Hyeok-Hwan Kwon;
Page : 219-224
Keywords : SINEWAVE DIMMER; SSR; SCR DIMMER; THEATERS; ENERGY EFFICIENCY;
Abstract
Today, High Social demand for Energy Saving. This have been Studied for the purpose, Having an Efficiency of much it, in IGBT DIMMER SYSTEM compared to the existing SSR,SCR Dimmer System.
The Method Two, The First is Dimming in Dimmer System How much Power loss Appears of A Comparison Experiment According to the output a SINEWAVE Strain, Comparative Measurements Experimental were Conducted with Oscilloscope. Second, When Dimming the sound has equipment by measuring the relative Size Decibel Experiment was conducted in Decibel Meter about the Equipment Noise. Results Thus Confirm SSR,SCR Dimmer IGBT SINEWAVE Dimmer more Efficiently.