Estimation of Power Production Potential from Natural Gas Pressure Reduction Stations in Pakistan Using ASPEN HYSYS
Journal: Mehran University Research Journal of Engineering and Technology (Vol.34, No. 3)Publication Date: 2015-07-01
Authors : Unar I.N.; Aftab A.; Abro M.;
Page : 301-308
Keywords : Pressure into Power; Sales Metering Station; Turbo Expanders; Natural Gas.;
Abstract
Pakistan is a gas rich but power poor country. It consumes approximately 1, 559 Billion cubic feet of natural gas annually. Gas is transported around the country in a system of pressurized transmission pipelines under a pressure range of 600-1000 psig exclusively operated by two state owned companies i.e. SNGPL (Sui Northern Gas Pipelines Limited) and SSGCL (Sui Southern Gas Company Limited). The gas is distributed by reducing from the transmission pressure into distribution pressure up to maximum level of 150 psig at the city gate stations normally called SMS (Sales Metering Station). As a normal practice gas pressure reduction at those SMSs is accomplished in pressure regulators (PCVs or in throttle valves) where isenthalpic expansion takes place without producing any energy. Pressure potential of natural gas is an untapped energy resource which is currently wasted by its throttling. This pressure reduction at SMS (pressure drop through SMS) may also be achieved by expansion of natural gas in TE, which converts its pressure into the mechanical energy, which can be transmitted any loading device for example electric generator. The aim of present paper is to explore the expected power production potential of various Sales Metering Stations of SSGCL company in Pakistan. The model of sales metering station was developed in a standard flow sheeting software Aspen HYSYS®7.1 to calculate power and study other parameters when an expansion turbine is used instead of throttling valves. It was observed from the simulation results that a significant power (more than 140 KW) can be produced at pressure reducing stations of SSGC network with gas flows more than 2.2 MMSCFD and pressure ration more than 1.3.
Other Latest Articles
- Analysis and Mitigation of Shunt Capacitor Bank Switching Transients on 132 kV Grid Station, Qasimabad Hyderabad
- Physical Cleaning of Lakhra Coal by Dense Medium Separation Method
- Use of GeoGebra in Primary Math Education in Lithuania: An Exploratory Study from Teachers' Perspective
- Performance Evaluation of Indian Technical Institutions Using PROMETHEE-GAIA Approach
- A Few Observations and Remarks on Time Effectiveness of Interactive Electronic Testing
Last modified: 2016-01-15 11:17:09