Bi-directional fault analysis of evaporator inspection system
Journal: International Journal of Advanced Smart Convergence(IJASC) (Vol.1, No. 1)Publication Date: 2012-05-31
Authors : Dae Ki Kang; Jeong Jin Kang;
Page : 57-60
Keywords : Automated Visual Inspection system (AVI); Software Fault Tree Analysis (SFTA); Software Failure Modes; Effects; & Criticality Analysis (SFMECA);
Abstract
In this paper, we have performed a safety analysis on an automotive evaporator inspection system. We performed the bi-directional analysis on the manufacturing line. Software Fault Tree Analysis (SFTA) as backward analysis and Software Failure Modes, Effects, & Criticality Analysis (SFMECA) as forward analysis are performed alternately to detect potential cause-to-effect relations. The analysis results indicate the possibility of searching and summarizing fault patterns for future reusability.
Other Latest Articles
- Development of Current Control System for Solar LED Street Light System
- Motor noise removal for determining gait events over treadmill walking using wavelet filter
- Association Analysis of Parkinson's Disease using Apriori Algorithm
- Design of Korean smart car driving information checking system
- File Modification Pattern Detection Mechanism Using File Similarity Information
Last modified: 2016-01-29 13:58:59