ResearchBib Share Your Research, Maximize Your Social Impacts
Sign for Notice Everyday Sign up >> Login

Empirical Modeling of Fouling Rate of Milk Pasteurization Process : A case study

Journal: International Journal of Advanced Smart Convergence(IJASC) (Vol.4, No. 1)

Publication Date:

Authors : ; ; ;

Page : 11-17

Keywords : empirical modeling; fouling; heat exchanger; milk; pasteurization.;

Source : Download Find it from : Google Scholarexternal

Abstract

Fouling in heat exchanger becomes a major problem of dairy industry and it increases the production cost. These are lost productivity, additional energy, additional equipment, chemical, manpower, and environmental impact. Fouling also introduces the risk of food safety due to the improper heating temperature which allow the survival of pathogenic bacteria in milk, introducing biofilm formation of pathogenic bacteria in equipments and spreading the pathogenic bacteria to milk. The aim of this study is to determine the fouling rate during pasteurization process in heat exchanger of pasteurized milk produced by Village Cooperative Society (KUD) “X” in Malang, East Java Indonesia by using empirical modeling. The fouling rate is found as 0.3945 oC/h with the heating process time ranged from 0 to 2 hours and temperature difference (hot water inlet temperature and milk outlet temperature) ranged from 0.654 to 1.636 oC. The fouling rate depends on type and characteristics of heat exchangers, time and temperature of process, milk type, age of milk, seasonal variations, the presence of microorganism and more. This results will be used to plan Cleaning In Place (CIP) and to design the control system of pasteurization process in order to maintain the milk outlet temperature as standard of pasteurization.

Last modified: 2016-02-17 16:00:42