Sonolog Test Sumur Minyak menggunakan Alat Total Well Management Echometer sebagai Well Analyzer Sumur di Pertamina EP Subang

Journal: Jurnal Elkomika (Vol.2, No. 2)

Publication Date:

Authors : ;

Page : 152-161

Keywords : sound waves; acoustic; Sonolog Test; Total Well Management; Well Analyzer;

Source : Downloadexternal Find it from : Google Scholarexternal

Abstract

Sonolog Test Method is a method using reflection properties of sound waves, is used for the analysis of the well. Sonolog Test Method using a Total Well Management (TWM) as Well Analyzer is used to obtain data for analysis of performance well. Information on well data can be obtained by using a gas gun as a source of sound waves that were fired into the well. Results reflection of the well recorded in the form of graphs recorded in the computer. Strong reflection (kick down) from the sound waves recorded on 14 827 seconds indicating fluid peak at a depth of 9161.24 feet from the surface. Casing pressure of 33.8 psig measured is lower than the pump intake pressure of 486 psig calculation results so that the casing pressure does not interfere with the production wells. Analysis of acoustic tubing collar reflection average of 31.19 ft each tubing, and a sound wave velocity of gas in the annulus of 1236 ft / sec, and it can be seen that the wave velocity in the annular gas directly related to the density of the gas. Well Analyzer of Echometer on Sonolog Test Method, helped see further opportunities to increase production as by analyzing the peak height of fluid in the well for which data is visible on the computer.

Last modified: 2016-03-15 17:01:42