PRESSURE DROP STUDIES IN WAVY CORRUGATED PLATE HEAT EXCHANGERS
Journal: International Journal of Mechanical Engineering and Technology(IJMET) (Vol.6, No. 12)Publication Date: 2015-12-28
Authors : B Sreedhara Rao; M Mayuri; Y Sarasija; G Rohini; R.C Sastry;
Page : 60-65
Keywords : Corrugated Plate Heat Exchanger; Pressure Drop; Reynolds Number; Friction Factor;
Abstract
Wavy type heat exchangers are one of the prominent corrugated plate heat exchangers. The experimental studies have been carried out on wavy type heat exchangers with glycerol and water as test fluids. The experimental work involves in studying the various factors affecting the fluid flow mostly Friction factor and Pressure Drop , where the energy losses are calculated across the wavy type corrugated plate heat exchanger. The pressure drop studies were carried out in a corrugated plate heat exchanger with different corrugation angles of 30˚, 40˚ and 50˚ and corrugation channel spacing of 15 mm. It has been found that the pressure drop increases with an increase in the corrugation angle and viscosity of test fluid. Experimental data has been plotted for pressure drop against Reynolds number and observed that the pressure drop increases with increase in the corrugated angle.
Other Latest Articles
- DESIGN AND ANALYSIS OF LEAF SPRING BY USING COMPOSITE MATERIAL FOR LIGHT VEHICLES
- THE INFLUENCE OF SHAPE AND SPATIAL DISTRIBUTION OF METAL PARTICLES ON THE THERMAL CONDUCTIVITY OF METAL-POLYMER COMPOSITES
- INFLUENCE OF VARYING H2S CONCENTRATIONS AND HUMIDITY LEVELS ON ImAg AND OSP SURFACE FINISHES
- SPRING BACK PREDICTION OF SHEET METAL IN DEEP DRAWING PROCESS
- DEXTERITY INDICES OF 6-UPS PARALLEL MANIPULATOR
Last modified: 2016-04-28 20:58:01