Evaluation of Response Reduction Factor and Ductility Factor of RC Braced Frame
Journal: Journal of Materials and Engineering Structures (JMES) (Vol.2, No. 3)Publication Date: 2015-09-18
Authors : Kruti Tamboli; J. A. Amin;
Page : 120-129
Keywords : RC frame building; Ductility; Pushover analysis; Response reduction factor;
Abstract
Response reduction factor is the factor by which the actual base shear force should be reduced, to obtain the design lateral force during design basic earthquake (DBE) shaking. The response reduction factor (R) is basically depends on Over strength (Rs), Ductility (R?), Redundancy (RR). So there is a need to come up with realistic R factors for different structural systems used in various countries. In the present study efforts are made to evaluate the response reduction factor and ductility of RC braced frame using nonlinear static pushover analysis. The types of the frame considered in this study are RC frame with X bracing at centre bay, RC frame with X bracing at alternate bays, shear wall at canter and alternate bays. The result of this study shows that R factor and lateral strength of RC frames are considerably affected by the types and arrangement of the bracing system.
Other Latest Articles
- Shear walls RC Frame interaction Lateral forces
- Investigate the Relationship between Economic Growth and Environmental Quality in D8 Member Countries
- Anaerobic Digestion of Cow Dung with Rumen Fluid
- Levels of Stress and Coping Strategies Used by Nursing Students in Asian Countries: An Integrated Literature Review
Last modified: 2016-05-01 19:14:37