Q-absorbance ratio spectrophotometric method for simultaneous determination of atenolol and ivabradine hydrochloride in synthetic mixture
Journal: Pharmaceutical and Biological Evaluations (Vol.3, No. 2)Publication Date: 2016-04-20
Authors : Pooja Patil; Hasumati A. Raj; Gautam B. Sonara;
Page : 224-230
Keywords : ;
Abstract
Objective: It describes Simultaneous estimation of simple, accurate, precise, robust and economical Q-Absorbance ratio spectrophotometric method for Atenolol and Ivabradine HCl in synthetic mixture. Objective of the study was to deliver information related to Ivabradine HCl and Atenolol combination’s analytical method.Methods: Absorbance ratio method for the ratio of absorbance at two selected wavelengths, one which is an iso-absorbtive point and other being the λ-max of one of the two components. Atenolol and Ivabradine HCl showed an iso-absorbtive point at 286.40 nm in methanol. The second wavelength used was 276 nm which is λmax of Atenolol in methanol. So it was economic in nature. The linearity was obtained in the concentration range of 20-100 ?g/ml for Atenolol and 2-10 ?g/ml for Ivabradine HCl. The concentration of the drugs was determined by using ratio of absorbance at iso-absorbtive point and at the λmax of Atenolol.Results: This method is linear for both drugs; in range 2-10 ?g/ml for Ivabradine HCl and 20-100 ?g/ml for Atenolol found at λmax of Atenolol 276nm (R2 = 0.9990) and at Iso-absorptive point 286.40 nm (R2 = 0.9998). % recovery for Ivabradine HCl found 100.47% and Atenolol 100.32%. And all validation parameter (Robustness, Ruggedness, Interday, Intraday) show %RSD >2%. And Limit of detection for Ivabradine HCl and Atenolol at λ1 (maximum wavelength) and λ2 (Iso-absorptive point) was found 0.309 and 0.181 respectively. % Assay for Ivabradine HCl and Atenolol found to be 100.58% and 100.13% respectively.Conclusions: The method was successfully applied to pharmaceutical synthetic mixture which was considered in approved patent which show no interference. The result of analysis has been validated statistically and by recovery studies. So this method accurate, precise, robust, rugged and economic in nature.
Other Latest Articles
- Development and validation of analytical method for clopidogrel bisulphate and irbesartan by simultaneous equation spectroscopic method
- Development and validation of reversed phase high performance liquid chromatography method for simultaneous estimation of Nebivolol HCl and Cilnidipine in combined tablet dosage form
- Simultaneous determination of mesalazine and rifaximin in synthetic mixture using spectrophotometric technique (simultaneous equation method)
- Rheumatoid arthritis: in past, present and future scenario
- Role of epigenetic mechanisms in various cancer therapies
Last modified: 2016-05-04 17:30:15