UNDER DISTORTED GRID VOLTAGE DIRECT POWER CONTROL OF DOUBLY FED INDUCTION GENERATOR

Journal: International Journal of Engineering Sciences & Research Technology (IJESRT) (Vol.5, No. 8)

Publication Date:

Authors : ; ;

Page : 1012-1016

Keywords : Direct power control (DP C); doubly fed induction generator (DFIG); harmonically distorted grid voltage; vector proportional integrated (VPI) regulator;

Source : Downloadexternal Find it from : Google Scholarexternal

Abstract

This paper presents a direct power control strategy for a doubly fed induction generator based wind power By analyzing the six times grid frequency power pulsation produced by the fifth and seventh grid voltage harmonic components, DPC strategy with vector proportional integrated (VPI) regulator has been proposed to impleme nt the smooth active and reactive power output of DFIG. The performance analysis of the proposed DPC strategy, including the steady and dynamic state performance, closed - loop operation stability, and rejection capability for the grid voltage distorted comp onent and back EMF compensation item has been investigated. The availability of the proposed DPC strategy with a VPI regulator is verified by experiment results of DFIG system under harmonically distorted grid condition.