ENHANCEMENT OF HEAT TRANSFER IN HELICAL COIL HEAT EXCHANGER FOR COUNTER FLOW ARRANGMENT
Journal: International Journal of Engineering Sciences & Research Technology (IJESRT) (Vol.5, No. 12)Publication Date: 2016-12-30
Authors : M.Sireesha; M.Ganesh Kumar; Ch.Kiran Kumar;
Page : 266-273
Keywords : Helical coil heat exchanger; rotameter; effectiveness; overall heat transfer coefficient.;
Abstract
Heat recovery is the capture of energy contained in the fluids otherwise that w ould be lost from the facility. The heat exchangers are the important in the engineering system with wide variety of applica tions including power plants, nuclear reactors, refrigeration, air conditioning system, heat recovery systems, chemical processing and food industries. Helical tube heat exchanger (HTHE) is a device which is used for heat recovery system because of fluid d ynamics inside the pipes of a helical coil heat exchanger offers certain advantages over the straight tubes. The experimental set up of the heat exchangers consist of a shell through which cold water flows and the hot water flows through the tube which con figured in helical tube in the set up. The centrifugal force developed due to the helical curvature of tubes resolve in the secondary flow development, which may be the key factor enhancements of heat transfer. The present project work is to investigate th e performance of the counter flow heat exchanger experimentally, analytically by using CREO & solid works for enhancement heat transfer coefficients of fluid in helical tube for pitch and curvature ratio and compare the experimental and analytical values o f helical coil heat transfer coefficient for counter flow arrangement.
Other Latest Articles
Last modified: 2016-12-06 21:33:54